What failure modes are possible in a transformer? How to identify and fix these failures?

Transformers are critical components in electrical power systems, and several failure modes can affect their operation. Identifying and addressing these failure modes promptly is essential to prevent costly downtime and ensure system reliability. Here are some common failure modes in transformers and how to identify and address them:

1. Insulation Failure:

Identification: Insulation failure can lead to a drop in insulation resistance, which can be detected by insulation resistance testing (megohmmeter testing).

Fix: Replace or repair damaged insulation materials, including bushings, leads, or the entire winding if necessary. Investigate the cause of the insulation failure, which could be due to overheating, moisture ingress, or contamination.

2. Overheating:

Identification: Overheating can be caused by excessive load, poor cooling, or loose connections. Elevated temperatures may be detected using temperature sensors and infrared thermography.

Fix: Reduce the load to within the transformer's rated capacity, ensure proper cooling, and tighten loose connections. Consider redesigning the cooling system if necessary.

3. Core Saturation:

Identification: Core saturation occurs when the magnetic core reaches its limit, causing distortion in the output waveform. This can be observed through harmonic distortion in current and voltage waveforms.

Fix: Install harmonic filters to mitigate core saturation issues. Evaluate the need for a different core material or design to prevent saturation.

4. Winding and Core Damage:

Identification: Visual inspection may reveal physical damage, such as cracks, warping, or deformations in the winding or core.

Fix: Repair or replace damaged components. For minor damage, winding repair can be performed, while major damage may necessitate rewinding or core replacement.

5. Oil Contamination and Deterioration:

Identification: Oil analysis, including dissolved gas analysis (DGA), can detect contaminants and gases produced during incipient faults. Darkening or foaming of the oil may also indicate issues.

Fix: Replace contaminated oil and address the underlying issue causing contamination. Modernize to eco-friendly and less flammable insulating fluids if applicable.

6. Bushing and Gasket Leaks:

Identification: Oil leaks, especially around bushings and gaskets, can be observed visually.

Fix: Repair or replace damaged bushings and gaskets. Tighten connections and ensure proper sealing.

7. Short Circuits:

Identification: Short circuits can cause overcurrent and generate a distinctive sound. Protective relays should trip in response to short circuits.

Fix: Investigate the cause of the short circuit, repair damaged components, and replace any affected winding sections.

8. Tap Changer Issues:

Identification: Tap changer malfunction may result in voltage regulation problems or no-load tap changer (NLTC) arcing. Monitoring voltage variations can help identify tap changer issues.

Fix: Clean, lubricate, and maintain the tap changer. If significant issues persist, consider repairing or replacing it.

9. Moisture Ingress:

Identification: Moisture ingress can be detected through moisture content analysis. Visual inspection may also reveal signs of moisture damage, such as rust or corrosion.

Fix: Address the source of moisture ingress, repair or replace damaged components, and maintain proper sealing.

It's important to conduct routine preventive maintenance, including visual inspections, oil sampling, and insulation resistance testing, to detect potential issues early. Additionally, consider adopting condition monitoring techniques, such as online monitoring and partial discharge testing, to continuously assess transformer health. Timely repairs and maintenance can help extend the life of a transformer and prevent costly failures.